You are currently viewing our forum as a guest, which gives you limited access to view most discussions and access our other features. By joining our community, at no cost, you will have access to post topics, communicate privately with other members (PM), respond to polls, upload content and access many other special features. Registration is free, fast and simple, so please join our community today!


Reply
 
LinkBack Thread Tools Search this Thread
Old 04-08-2008, 08:36 PM   #1
Registered User
Personal Sales Rating: (0)
 
ThomasJ's Avatar
 
Join Date: Aug 2005
Location: Lafayette IN
Posts: 228
Brand new craftsman air compressor trips breaker instantly

I just got a new craftsman air compressor and im having problems with it. When I first plugged it in, it did nothing, and I mean nothing. After switching it on and off a few times I got a quick click and im intantly standing in complete darkness. After feeling my way to the breaker box (in garage) i reset the breaker, try it and it trips again. I reset and turn the compressor by hand to be sure it feels ok. All is good and spun freely. I try it again and it starts. I let if fill up and kick off. I hook up an air sander to drain some air and make it kick back on. It gets down to about 90 psi and still nothing, no clicks, just silence. Its supposed to cut in at 120 and out at 150. so Im standing there scratching my head on why it didnt kick on and then I hear a click and then darkness again.

long story short , sometimes it starts... sometimes it doesnt. Once its running it works great. but it only starts about 20% of the time.

Also, its not like it jammed up or binding or anything like that. Like I said, just a quick click and then trips the breaker. I have a 20amp breaker in my garage. The only other thing on in the garage were two 75w light bulbs in the ceiling and a 45w bulb in the garage door opener. I tried with all these lights off and got the same results. I also took it in the laundry room (30 amp) and got the same results.

Anybody know what to look for first or should I just take it back? Im not sure if they have more. I hope they do because I was planning some body work on the 4Runner this weekend
This ad is not displayed to registered members.
Register your free account today and become a member on Yotatech!
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer.

The Pit bull problem

If you live in Chicago please sign.
ThomasJ is offline   Reply With Quote
Old 04-08-2008, 08:46 PM   #2
Contributing Member
Personal Sales Rating: (0)
 
Elton's Avatar
 
Join Date: Jul 2005
Location: Siletz,Oregon
Posts: 12,278
elton hostler
Send a message via AIM to Elton Send a message via MSN to Elton
take it back and try a different one
__________________
07 Tundra d-cab limited 5.7L 4x4 was my moms r.i.p 3/19/11
98 4runner SR5 3.4L 5spd 4x4 E-Locker sold 10-2-11
91 4runner SR5 4x4 3.0L 5spd Totaled 5/13/06
97 honda civic lx 4dr ls vtec
Elton is offline   Reply With Quote
Old 04-08-2008, 09:09 PM   #3
This one time, at band camp
Personal Sales Rating: (20)
Staff
 
DeathCougar's Avatar
 
Join Date: Jan 2003
Location: Marysville, WA
Posts: 17,508
Send a message via AIM to DeathCougar Send a message via Yahoo to DeathCougar
its not the compressor. Its your wiring.

We had the EXACT same "issue" with a craftsman compressor (the black tank one) at work. Problem was the voltage drop between the breaker box and the outlets. The wiring was not large enough, and the current strong enough to handle the current draw used by the compressor.

You need to get an electrician out there to remedy that problem, or you will continue to have the same issue.

trust me when i say there is NOTHING wrong with the compressor.
__________________
Tacoma miniheader install kit Now available! Click here for ordering information

Quote:
Originally Posted by BigBluePile View Post
Hmmm, dunno. Ask the oem Nazi DC.
Quote:
Originally Posted by kiyobrown View Post
I'll cut you.
DeathCougar is online now   Reply With Quote
Old 04-08-2008, 09:14 PM   #4
Registered User
Personal Sales Rating: (0)
 
90inworks's Avatar
 
Join Date: Nov 2006
Location: Sedro Woolley washington
Posts: 794
Send a message via MSN to 90inworks
Ours does this every now and than. Plug it in closer to the box and try and only have the things that need to be plugged in, in.
__________________
1994 p/u v-6 4x4 ex-cab

Mods,
flowmaster 40 series
cobra cb
tinted windows
alpine 6 button cd player
10in mtx square
all sorts of trail lights
SAS with 8in lift
3in body lift
35in toyo m.t's tires
Soon to be mods,
tires, wheels, rocker pannels, alarm, Air lockers. :)
90inworks is offline   Reply With Quote
Old 04-08-2008, 09:23 PM   #5
Registered User
Personal Sales Rating: (0)
Threadstarter [OP]
 
ThomasJ's Avatar
 
Join Date: Aug 2005
Location: Lafayette IN
Posts: 228
hmm. thats not what I want to hear considering I rent this place. Its a duplex and I doubt they would do it for me.

Im not telling you your wrong, but what about the compressor not even doing anything in the beginning. It didnt even click or trip the breaker. It was like it wasnt even plugged in. The first 15-20 times I turned it on it did nothing.

Also, is it common to have this wiring problem in homes? These places are only about 4 years old. The outlet I was using is only about 7 inches from the main box.
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer.

The Pit bull problem

If you live in Chicago please sign.
ThomasJ is offline   Reply With Quote
Old 04-08-2008, 10:05 PM   #6
Registered User
Personal Sales Rating: (0)
 
the_supernerd's Avatar
 
Join Date: Sep 2002
Location: Sonora, CA
Posts: 1,332
How many watts or amps does the compressor use? It should have a small tag on it somewhere that says.
__________________
-Anthony
1987 4x4 Carbureted 22R truck-Daily Driver
1988 4x2 Carbureted 22R truck-Current Project Truck
the_supernerd is offline   Reply With Quote
Old 04-08-2008, 10:57 PM   #7
Registered User
Personal Sales Rating: (0)
Threadstarter [OP]
 
ThomasJ's Avatar
 
Join Date: Aug 2005
Location: Lafayette IN
Posts: 228
well it says 15 amp on the website. Here are the specs

http://www.sears.com/shc/s/p_10153_1...+%26+Inflators
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer.

The Pit bull problem

If you live in Chicago please sign.
ThomasJ is offline   Reply With Quote
Old 04-08-2008, 11:22 PM   #8
Registered User
Personal Sales Rating: (0)
 
the_supernerd's Avatar
 
Join Date: Sep 2002
Location: Sonora, CA
Posts: 1,332
How many amps is the breaker rated for that is on the circuit that you are using for the air compressor? Try plugging it in to a circuit with a breaker that is rated at more than 20 amps. The air compressor should be the only thing on the circuit.

I kind of remember hearing somewhere that a breaker blows at 70% or 80% of its rated amperage or something like that. 15 amps would be right at the limit if that is true.
__________________
-Anthony
1987 4x4 Carbureted 22R truck-Daily Driver
1988 4x2 Carbureted 22R truck-Current Project Truck
the_supernerd is offline   Reply With Quote
Old 04-09-2008, 06:54 AM   #9
Registered User
Personal Sales Rating: (0)
 
Join Date: Aug 2005
Posts: 1,769
I have the same compressor but a different brand. The only time I haven't been able to get it to fire up is when I am using an extension cord that is too small of a guge & there is too much of an amperage drop. The fix was to upgrade the cord. If you are plugging into a 20amp circut 7 feet away from the box, you should have no problem at all. You should take it back to the store.
celica is offline   Reply With Quote
Old 04-09-2008, 07:38 AM   #10
Registered User
Personal Sales Rating: (0)
 
UncleBob's Avatar
 
Join Date: Jan 2007
Location: Middleburg, FL
Posts: 614
I have had 2 of the Craftsman compressors very similar to that, and never had any issues (other than losing my hearing) wherever I use them.

I, too, think the compressor is at fault.
__________________
Daily: 1990 2nd Gen 4-Runner SR5 V6
Toy: 1988 1st Gen 4-Runner SR5 V6
UncleBob is offline   Reply With Quote
Old 04-09-2008, 07:38 PM   #11
Registered User
Personal Sales Rating: (0)
Threadstarter [OP]
 
ThomasJ's Avatar
 
Join Date: Aug 2005
Location: Lafayette IN
Posts: 228
Today after work a buddy and I took the compressor over to his house and tried it. It worked perfectly fine. He has a 15 amp circuit on the outlet we used. I cycled it about ten times and didnt have a single problem, not even a hint of trouble.

I brought it back to my house and tried it again and it still tripped the 20amp breaker instantly. The only other oulet in the garage is the one in ceiling for the garage door opener. We put the compressor up on the gate of my runner so the cord would reach up there and it worked fine. I started it up about 5 or 6 times. The confusing part is that the cieling outlet is on the same breaker as the one I was having problems with. When plugged into the cieling outlet It even started with my lights on and refridgerator plugged. I did see a slight dim of the lights upon initial start but that is normal.

I dont think an extention cord would be good to run all the way from the ceiling and down the wall. Would probly have to be about 25' of cord.

So I have narrowed it down to that single outlet that has the problem. Im not comfortable with messing with electricity so I guess im going to try to find somebody I know or a friend who knows what to do next.
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer.

The Pit bull problem

If you live in Chicago please sign.
ThomasJ is offline   Reply With Quote
Old 04-16-2008, 04:00 PM   #12
Registered User
Personal Sales Rating: (0)
 
Taro's Avatar
 
Join Date: Jan 2008
Location: Los Angeles
Posts: 230
Maybe its the outlet. Or maybe that specific breaker is bad or says 15 but isnt.

And although the compressor pulls 15amps running, it pulls more than that at first, the surge amp draw.
Taro is offline   Reply With Quote
Old 04-16-2008, 04:30 PM   #13
Contributing Member
Personal Sales Rating: (0)
 
Dublin's Avatar
 
Join Date: Feb 2004
Location: Appleton, Wi. USA
Posts: 892
A few probable causes. #1 Out go the lights, Typically rental units are wired as cheaply as possible (this doesn't make it a bad wiring job, just cheap). What this means is no dedicated circuits other than what's required. Also I would be willing to bet there are other things on that circuit, possibly bathroom GFCI's. #2 The receptacle may be installed the quick and easy ( it may be back stabbed rather than on the termination screws) not the most solid connection for items with a large in rush current. The label may say 15 amp circuit ( usually running current) but the start up ( in rush) may be 20). Circuit breakers are normally designed to run at 80 percent load ( a 15 amp is really good for 12 amps and a 20 is good for 16 amps) a good breaker will only work at the full rating for short term. #3 possible bad terminations at the panel (grounded and grounding connections the green or bare copper and the white or gray also the breaker connection) Since the lights go out any splice or connection along the way could be loose (lights, receptacles, switches) #4 Is the receptacle a GFCI (has the reset/test buttons) or the breaker a GFCI ( has the yellow test button) both not ideal for motor loads. Good luck, I'd come over and check it out but your a bit of a drive away.
__________________
94 4Runner 4x4, V6 Auto, Outlaw II's with BFG 33x12.5x15 on stock suspension (no lift), Kenwood KDC-MVP Sirius/MP3 player, Bushwacker extenda-flares, 1700 watt power inverter, Air intake mod, Radio Shack CB, GPS, Swing arm tire carrier, modified 1st gen Toyota 4Runner Rollbar, Aisin manual hubs, 87 inclinometer, Toyota Brush guard. Where ever you go, there you are. I started out with nothing & still have most of it left.
Dublin is offline   Reply With Quote
Old 04-16-2008, 04:30 PM
Yotatech
4WD Truck




Paid Advertisement
Reply

Tags
2003, 4runner, air, breaker, circuit, compressor, compressorr, craftsman, fuse, manual, start, trip, tripping, trips, watts

Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Removing Air Conditioning or converting to air compressor??? NMcruser Offroad Tech 8 11-28-2008 12:46 PM
Craftsman air compressor for onboard air?? 89silverpu The Classifieds GraveYard 20 04-02-2008 01:22 PM
A/C Compressor turned Air Compressor Kiff 86-95 Trucks & 4Runners 13 08-15-2007 05:59 PM
WTB: pop can sized air compressor (for air horn) Brendan The Classifieds GraveYard 1 01-03-2007 07:13 PM
12v craftsman 300psi suv/truck compressor ? r0cky 95.5-2004 Tacomas & 96-2002 4Runners 13 07-29-2004 03:08 PM