Brand new craftsman air compressor trips breaker instantly
I just got a new craftsman air compressor and im having problems with it. When I first plugged it in, it did nothing, and I mean nothing. After switching it on and off a few times I got a quick click and im intantly standing in complete darkness. After feeling my way to the breaker box (in garage) i reset the breaker, try it and it trips again. I reset and turn the compressor by hand to be sure it feels ok. All is good and spun freely. I try it again and it starts. I let if fill up and kick off. I hook up an air sander to drain some air and make it kick back on. It gets down to about 90 psi and still nothing, no clicks, just silence. Its supposed to cut in at 120 and out at 150. so Im standing there scratching my head on why it didnt kick on and then I hear a click and then darkness again.
long story short , sometimes it starts... sometimes it doesnt. Once its running it works great. but it only starts about 20% of the time. Also, its not like it jammed up or binding or anything like that. Like I said, just a quick click and then trips the breaker. I have a 20amp breaker in my garage. The only other thing on in the garage were two 75w light bulbs in the ceiling and a 45w bulb in the garage door opener. I tried with all these lights off and got the same results. I also took it in the laundry room (30 amp) and got the same results. Anybody know what to look for first or should I just take it back? Im not sure if they have more. I hope they do because I was planning some body work on the 4Runner this weekend
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer. The Pit bull problem If you live in Chicago please sign. |
|
|
|
| Sponsored Links |
|
|
|
|
#3 (permalink) | |
|
Contributing Member
|
its not the compressor. Its your wiring.
We had the EXACT same "issue" with a craftsman compressor (the black tank one) at work. Problem was the voltage drop between the breaker box and the outlets. The wiring was not large enough, and the current strong enough to handle the current draw used by the compressor. You need to get an electrician out there to remedy that problem, or you will continue to have the same issue. trust me when i say there is NOTHING wrong with the compressor.
__________________
Need that hard to find part? Nix99 Used Toyota and Lexus parts! Quote:
|
|
|
|
|
|
|
#4 (permalink) |
|
Registered User
|
Ours does this every now and than. Plug it in closer to the box and try and only have the things that need to be plugged in, in.
__________________
FRIENDS: Bail you out of jail and tell you what you did was wrong. TRUE FRIENDS: Will be sitting next to you saying, Damn...that was fun " 1994 p/u v-6 4x4 ex-cab Mods, flowmaster 40 series cobra cb tinted windows alpine 6 button cd player 10in subs 4in susp. lift 3in body lift 35in tires front locker Soon to be mods, tires, wheels, rocker pannels, alarm, Air lockers. :) |
|
|
|
|
|
#5 (permalink) |
|
Registered User
Join Date: Aug 2005
Location: Lafayette IN
Posts: 233
|
hmm. thats not what I want to hear considering I rent this place.
Its a duplex and I doubt they would do it for me. Im not telling you your wrong, but what about the compressor not even doing anything in the beginning. It didnt even click or trip the breaker. It was like it wasnt even plugged in. The first 15-20 times I turned it on it did nothing. Also, is it common to have this wiring problem in homes? These places are only about 4 years old. The outlet I was using is only about 7 inches from the main box.
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer. The Pit bull problem If you live in Chicago please sign. |
|
|
|
|
|
#6 (permalink) |
|
Registered User
Join Date: Sep 2002
Location: Sonora, CA
Posts: 1,063
|
How many watts or amps does the compressor use? It should have a small tag on it somewhere that says.
__________________
-Anthony 1987 4x4 Carbureted 22R truck Grill & brush guard | Roll bars | Bed liner | Tubular rear bumper | JVC CD-player | Custom 6.5" rear speaker boxes with 6.5" Sony X-Plods | Polk 3.5" speakers in dash | Fog & driving lights Future mods: Dynomax muffler | Spray on bed liner | Custom switch for fog & driving lights |
|
|
|
|
|
#7 (permalink) |
|
Registered User
Join Date: Aug 2005
Location: Lafayette IN
Posts: 233
|
well it says 15 amp on the website. Here are the specs
http://www.sears.com/shc/s/p_10153_1...26+Inf lators
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer. The Pit bull problem If you live in Chicago please sign. |
|
|
|
|
|
#8 (permalink) |
|
Registered User
Join Date: Sep 2002
Location: Sonora, CA
Posts: 1,063
|
How many amps is the breaker rated for that is on the circuit that you are using for the air compressor? Try plugging it in to a circuit with a breaker that is rated at more than 20 amps. The air compressor should be the only thing on the circuit.
I kind of remember hearing somewhere that a breaker blows at 70% or 80% of its rated amperage or something like that. 15 amps would be right at the limit if that is true.
__________________
-Anthony 1987 4x4 Carbureted 22R truck Grill & brush guard | Roll bars | Bed liner | Tubular rear bumper | JVC CD-player | Custom 6.5" rear speaker boxes with 6.5" Sony X-Plods | Polk 3.5" speakers in dash | Fog & driving lights Future mods: Dynomax muffler | Spray on bed liner | Custom switch for fog & driving lights |
|
|
|
|
|
#9 (permalink) |
|
Registered User
Join Date: Aug 2005
Location: Calgary, AB Canada
Posts: 1,765
|
I have the same compressor but a different brand. The only time I haven't been able to get it to fire up is when I am using an extension cord that is too small of a guge & there is too much of an amperage drop. The fix was to upgrade the cord. If you are plugging into a 20amp circut 7 feet away from the box, you should have no problem at all. You should take it back to the store.
__________________
Matt 2003 4-Runner Limited - Couldn't stay away from the runner 2003 Sequoia Limited 1989 Supra Turbo 1992 4r, 5spd V6 Sold |
|
|
|
|
|
#10 (permalink) |
|
Registered User
Join Date: Jan 2007
Location: Middleburg, FL
Posts: 615
|
I have had 2 of the Craftsman compressors very similar to that, and never had any issues (other than losing my hearing) wherever I use them.
I, too, think the compressor is at fault.
__________________
Daily: 1990 2nd Gen 4-Runner SR5 V6 Toy: 1988 1st Gen 4-Runner SR5 V6 |
|
|
|
|
|
#11 (permalink) |
|
Registered User
Join Date: Aug 2005
Location: Lafayette IN
Posts: 233
|
Today after work a buddy and I took the compressor over to his house and tried it. It worked perfectly fine. He has a 15 amp circuit on the outlet we used. I cycled it about ten times and didnt have a single problem, not even a hint of trouble.
I brought it back to my house and tried it again and it still tripped the 20amp breaker instantly. The only other oulet in the garage is the one in ceiling for the garage door opener. We put the compressor up on the gate of my runner so the cord would reach up there and it worked fine. I started it up about 5 or 6 times. The confusing part is that the cieling outlet is on the same breaker as the one I was having problems with. When plugged into the cieling outlet It even started with my lights on and refridgerator plugged. I did see a slight dim of the lights upon initial start but that is normal. I dont think an extention cord would be good to run all the way from the ceiling and down the wall. Would probly have to be about 25' of cord. So I have narrowed it down to that single outlet that has the problem. Im not comfortable with messing with electricity so I guess im going to try to find somebody I know or a friend who knows what to do next.
__________________
95 3.0 4Runner, 4.88 gears, 32x11.5 Yoko,s on 15x8-3.75 AR wheels, Superwinch hubs, Cruiser coils, Skyjacker shocks, Skyjacker steering stabilizer. The Pit bull problem If you live in Chicago please sign. |
|
|
|
|
|
#12 (permalink) |
|
Registered User
Join Date: Jan 2008
Posts: 184
|
Maybe its the outlet. Or maybe that specific breaker is bad or says 15 but isnt.
And although the compressor pulls 15amps running, it pulls more than that at first, the surge amp draw. |
|
|
|
|
|
#13 (permalink) |
|
Contributing Member
Join Date: Feb 2004
Location: Menasha, Wi. USA
Posts: 868
|
A few probable causes. #1 Out go the lights, Typically rental units are wired as cheaply as possible (this doesn't make it a bad wiring job, just cheap). What this means is no dedicated circuits other than what's required. Also I would be willing to bet there are other things on that circuit, possibly bathroom GFCI's. #2 The receptacle may be installed the quick and easy ( it may be back stabbed rather than on the termination screws) not the most solid connection for items with a large in rush current. The label may say 15 amp circuit ( usually running current) but the start up ( in rush) may be 20). Circuit breakers are normally designed to run at 80 percent load ( a 15 amp is really good for 12 amps and a 20 is good for 16 amps) a good breaker will only work at the full rating for short term. #3 possible bad terminations at the panel (grounded and grounding connections the green or bare copper and the white or gray also the breaker connection) Since the lights go out any splice or connection along the way could be loose (lights, receptacles, switches) #4 Is the receptacle a GFCI (has the reset/test buttons) or the breaker a GFCI ( has the yellow test button) both not ideal for motor loads. Good luck, I'd come over and check it out but your a bit of a drive away.
__________________
94 4Runner 4x4, V6 Auto, Outlaw II's with BFG 33x12.5x15 on stock suspension (no lift), Kenwood KDC-MVP Sirius/MP3 player, Bushwacker extenda-flares, 1700 watt power inverter, Air intake mod, Radio Shack CB, GPS, Swing arm tire carrier, modified 1st gen Toyota 4Runner Rollbar, Aisin manual hubs. Off roading Rocks! |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Removing Air Conditioning or converting to air compressor??? | NMcruser | Offroad Tech | 8 | 11-28-2008 01:46 PM |
| Craftsman air compressor for onboard air?? | 89silverpu | Misc Stuff (Vehicle Related) | 20 | 04-02-2008 02:22 PM |
| A/C Compressor turned Air Compressor | Kiff | 86-95 Trucks & 4Runners | 13 | 08-15-2007 06:59 PM |
| WTB: pop can sized air compressor (for air horn) | Brendan | Items Wanted | 1 | 01-03-2007 08:13 PM |
| 12v craftsman 300psi suv/truck compressor ? | r0cky | 95.5-2004 Tacomas & 96-2002 4Runners | 13 | 07-29-2004 04:08 PM |